Spotify
Hi guys,
It's there any way to integrate Spotify or other online audio stream platform on Comfortclick?
Kind Regards,
Filipe Coelho
MCO HOME RELAYS
MCO home relays are getting added in jigsaw z wave but the issue is with the feedback ( status ). We have used jigsaw z wave and also the UZB stick
but still no success. The same stick over any other server or computer gives feedback for MCO home relays. Can anyone please comment ?
Thermostat
I have an issue with thermostat.
Current Temperature=21ºC
Setpoint = 24ºC
Mode=Heating
Value=False ¿?¿?
Hysteresis=0.5ºC (I assume that is symetric)
If I change mode to Cooling then Value=True
What's wrong?
Thanks
Profile key does not match the server key. Possible security violation.
Hello!
I used to connect to my server using the IP address and always worked just fine(for local and remote connection). Now i'm trying to conect using the Access ID and i get a error message "Can not connect with this profile. Profile key does not match the server key. Possible security violation."
The odd thing is that when i switch back to connect by the IP it work whitout any problem.
Any ideia why this is happening and how to fix it?
Windows IoT
Can BoS server be installed in Windows IoT?, I know that WIoT don't support Windows 32 bits apps.
Regards
webinterface
Is it any way to turn of the zoom in the web UI (browser).
When double-tap in the webbrowser when using a touchscreen the comfortclick zoom in the browser and its hard to get back to the standard zoom whitout reload the page. The zoomlevel in the webbrowsersetting don't have any effect on the zoom level on the comfortclic. The browser setting stays on 100% all time.
It doen't appears on any other webpage, just comfort click.
MODBUS WITH PRODUAL HLS 44 Thermostat
I am trying to integrate Modbus Thermostat ( Produal HLS 44 ) with Jigsaw Z wave via RS 485 ( RTU ). The register details are mentioned below :-
Holding Register Address 1 ( 40001 ) = FAN SPEED CONTROL WRITE
Holding Register Address 2 ( 40002 ) = SET POINT WRITE
Input Register Address 18 ( 30018 ) = SET POINT BY USER
Input Register Address 19 ( 30019 ) = FAN CONTROL BY USER
Those Address were verified using MODSCAN 32 and found to be correct.
Now in jigsaw, the scenario is different. The setup was :-
ACTUALLY ADDRESS 18 IS FOR SET POINT BUT I AM GETTING THE SET POINT IN ADDRESS 17 ( 18 - 1 )
SIMILARLY ADDRESS 19 IS FOR FAN SPEED AND I AM GETTING IN ADDRESS 18 ( 19 - 1)
So what we have seen is for input register, we need to deduct -1 with the address mentioned in datasheet.
REGARDING THE HOLDING REGISTER 1 AND 2, IT IS NOT WORKING. I AM ABLE TO GET DATA FROM INPUT REGISTER BY DEDUCTING THE ADDRESS BY 1. BUT I AM NOT ABLE TO WRITE ANYTHING IN HOLDING REGISTER.
ALSO THE VALUE FROM INPUT REGISTER IS LIKE 280, 275, 220. WE NEED THE VALUE LIKE 28, 27.5, 22 ( divided by 10 ).
CAN YOU PLEASE SUPPORT ?
iOS Client font or formatting issue
I think this is a bug, but please tell me if I am just doing something wrong
The font on the iPhone bOS client is proportionally larger than on either the Windows or the Android tablet app so that screens that look fine on Windows or Android do not work on the iphone because much of the text is missing. Effectively you get 3 lines of text on the Windows and Andiod client but 2 on the iphone so the last line is always missing, (and that is often where things like temp is showing). It does not seem to matter how many tiles you have on a page. If you make the tiles bigger, (by having less rows), it just makes the two lines of text larger, it does not show more lines