Dim Hue lights with KNX
Hi,
I´m trying to dim my Hue lights with a KNX "one button dimming" sensor, but without any luck.
Is this at all possible, or am I wasting my time?
Thank you,
Jigsaw KNX
Hi there, I have Jigsaw installed and connected to KNX bus.
But since then whenever I try to set new KNX devices in ETS, I get error message "More than one device is in programming mode". I have to shutdown Jigsaw to assign an address to new KNX device.
Do I have to do some additional setup steps to connect Jigsaw to KNX, I guess it has to be something with Jigsaw being in programming mode?
Thank you for your help, Regards
Sonos
cześć,
1. jak wysłać ścieżkę dźwiękową do sonos?
2. czy możesz przeczytać wiadomość głosową z bos na głośniku sonos?
3. czy możesz zamienić listy utworów i radio na sonos z bos?
Z-wave device connected through FIBARO
Hello,
I have a YALE lock YDM3168 connected to bOS Colibri through FIBARO HC3. I have made some programs and I am able to control it and to read its position. The problem is that from time to time the HC3 seems to lose its connection with COLIBRI even if they are in the same LAN all the time and there are no any interruptions in the network. I don't know if the problem is caused by COLIBRI or by HC3 itself. By disabling and enabling back the FIBARO gateway in the configurator it comes back online.
Unfortunately I cannot yet connect the door lock directly to COLIBRI because of the Z-WAVE driver limitations so I am looking for a possibility to revive the connection between HC3 and COLIBRI from time to time. Something like keep alive. Anyone has any ideas?
Thanks,
Laurentiu
Dimmer relative, down button can't be used
Hello,
I added a dimmer switch (3.007 Control Dimming) in my project, and I can't use on the down button control.
After I edit the button it switch to the up control. Even in the dimmer template is the same issue.
Is this a bug ? It can be fixed ?
alexa
2 weeks ago I have done my setup with Alexa. All works fine.
Today the Light turned on without any command.
I'm wondering if there are any security breaches with the Alexa echo.
Any hints?
How to send MinMaxAvg to bus
Hello,
I would like to send an avg value (from the tast MinMaxAvg) of 3 values to the bus as a status (1byte).
Have anyone an idea how to do that?
Thanks ans best regards.
Michael
Filter NaN values from Modbus
Hello, I have a problem with Modbus wrong reading values. I have a table with the Power from SMA Modbus Device, this values are normaly between -10kw to 10kw but sometimes this value is readed wrong and set to max value of Input Variable, this situation make that the graph visualized wrong, exist the possibility to filter the values?
Thx
Unable to discover BACNET device
Hi, i have a Bacnet Controller conected to my network( T3000 ) and i am unable to discovery it through comfortclick
i am able to find it through the main controller software and through YABE (BACNET Explorer)
tryed connecting the device directly to my PC and disabling all the firewall and still do not work. any other advice??
SMA Tripower 10 Modbus communication problem
Hello,
I'm trying to connect with a SMA Tripower via Modbus TCP and I can connect with it but when I try to read registers the Tripower response NaN values all the time, I try to change the Slave ID and I try to read diferent adreces but doesn't work, I used the SMA example of the web and I make a new Modbus connection too, can you help me please. Thank you.
Customer support service by UserEcho