Enter forum description here ...
0
Under review

reduce max brightness during night?

Dave De Busschere 6 years ago in Devices / KNX updated 6 years ago 2

Hi,

I want to reduce the maximum brightness (of lights in a group) to 50% instead of 100% during night.

Anyone an idea how to configure this?

0
Under review

Warning message when web browser uses HTTPS connection

Claude Pey 6 years ago in Devices / Http updated by ComfortClick Support 6 years ago 1

Hi Everyone !

When I try to connect via https, the web browser shows a warning message (SITE NOT SECURE).

Is it a meaning to avoid this warning ?

That's not user friendly for the final user.

Thanks for your help.

Claude.

0
Under review

buttons & lighting "night mode"

Dave De Busschere 6 years ago in Devices / KNX updated 6 years ago 5

Hello,

I'd like to use the night mode in the buttons (light up and night).

and at the same time i wan't to have the lighting in the bedroom area (toilet, bedrooms, halway,..) to work at ca. 40%.

All lights are DALI dimmable. 

I made a group 3/3/4 night buttons where i put the 4(general) LED - brightness mode in.

What do i have to do in bosconfig for the nightmode buttons and what for the lights to go max. 40%?


Thanks,

Image 1720

0

Reading signal (Status) for a KNX 4 binary input

Aladdin Aladdinsultan 6 years ago in Devices / KNX updated 6 years ago 4

Hi dears,, 

I have an important question,, so plz help to answer it,, 

I have hotel project,, the owner needs to know if the rooms are (occupied / empty) as a simple solution, using a KNX 4 binary input modules,,


so my question is can i integrate these knx modules with jigsaw, to read/know each room status as (occupied /empty)?? 

Note: in this KNX system,  I will use KNX Power Supply and KNX 4 binary input modules.. 

Regards,, 

Aladdin Sultan 


0

KNX Dali Gateway

Dave De Busschere 6 years ago in Devices / KNX updated by Fredrik Sandblom 6 years ago 13

I have some some dimming lights (controlled buy dali gateway), they are programmed in ETS and working fine.

Now i'm trying to control theme with comfort click without succes.

I have the following adresses:

3/4/0 switch (switch)

3/4/1 dimming (dimming control)

3/4/2 value (percentage 0-100%)

3/4/3 status (switch)

I used in comfort click the following adress:

Address: 3/4/0 switch

status address: 3/4/2

resutl:

the slide goes directly back to 0

the light does nothing 

0
Under review

Access Control ABB

Giordano Olmi 6 years ago in Devices / KNX updated 6 years ago 2

Hi, I have the system ABB for Hotel access control

The system ABB used two group address and they are proprietary telegrams

If the composition is known is possible to read the telegram?

Do you have one exemple?

Best regard

Giordano

0
Under review

ChangeStationByUri(stationName, streamingUrl)

Giordano Olmi 6 years ago in Devices / Sonos updated by Richard 6 years ago 4

Hi, I would like to use the function "ChangeStationByUri(stationName, streamingUrl)" in the sonos system

Do you have the example?

Best regards

Giordano

0
Under review

zwave node settings error

Andy Gill 6 years ago in Devices / Z-Wave updated by Richard 6 years ago 8

Getting this when I try and open node setrtings in newly included device (Fibaro twin relay).

Image 1621

0
Under review

HTTP device stopped working

Calin Birtocean 6 years ago in Devices / Http updated 6 years ago 2

Hello,

The http device stopped after few months working without any issues. Here is the debug message while trying to send the command:

Debug : 10/26/2018 19:45:41 : Devices\http : Exception : GetResponseCallbackWebException : The underlying connection was closed: An unexpected error occurred on a send. at System.Net.HttpWebRequest.EndGetResponse(IAsyncResult asyncResult)
at BOSCommon.Drivers.BOSHttpClient.GetResponseCallback(IAsyncResult result)System.IO.IOException: Authentication failed because the remote party has closed the transport stream.
at System.Net.TlsStream.EndWrite(IAsyncResult asyncResult)
at System.Net.PooledStream.EndWrite(IAsyncResult asyncResult)
at System.Net.ConnectStream.WriteHeadersCallback(IAsyncResult ar)

The encoding is UTF8 and parser type Json. 

Same command gets executed when it is launched from google chome browser from the same server where the bOS is installed.

Could you please advise what the problem should be? 

Thanks,

Calin

0
Under review

Fibaro

John 6 years ago in Devices / Z-Wave updated by ComfortClick Support 6 years ago 8

Hi there friends,,

I’m new to comfortclick and I’m trying to add Fibaro controller (HC2) in the software to control the Fibaro devices already in the HC2.

Can you please help and guide me on how to do that?

Your help would be highly appreciated