Are Solar Edge inverters being supported?

Fred Hartman 6 years ago in bOS Configurator / Devices updated by Ricardo Pinto | visiontech pt 6 years ago 1

Hello,

I was wandering if inverters from Solar Edge are being support in same way as SMA inverters are supported.

See link to website: https://www.solaredge.com/us/products/pv-monitoring#/


Regards,

Fred

0
Under review

How to change date format

andrew sparrow 6 years ago in bOS Configurator updated by ComfortClick Support 6 years ago 1

How do i change the date to a UK format i.e. dd/mm/yyy and not mm/dd/yyy

0

d-link camera

Guillem Morey 7 years ago in bOS Configurator / Devices updated 6 years ago 1

I have a D-Link camera DCS-930L, I know is a lame camera, but I'm not able connect to the camera, I'm using this link http://admin:admin@192.168.220.103/mjpeg.cgi with VLC client and works, with Chrome too works and with FireFox too.

BOS Config always set to false Online and Streaming vars.


Any idea?.


Camera config

Username:admin

Password:admin

IP:192.168.220.103

Video Size:640:480

JPEG source:--

Refresh time:1000 (default)

Mode:Direct (I have tried all modes)

WanIP:--

MJPEG Source: mjpeg.cgi (tried winth slash before name)

MPEG Source:-- (too tried with video.cgi



Best Regards


0
Under review

Camera configurator bad login

Kristián Vojčík 7 years ago in Devices / Cameras updated by Tilen Suhadolnik 6 years ago 9

Hello. I ran into problem with onvif configurator in bOS. I click on configurator and see all camera but if I try to add it I enter Name and Password and get bad login error. And name and password work on other onvif program. Please help.

0
Under review

graph not plotting

Kresimir Marusic 7 years ago in bOS Configurator / Themes updated by ComfortClick Support 6 years ago 4

I have analog data loggers which records temeperatures in each room. 

I use that data to plot graphs. For some time now graphs simple wont plot any more in bOS Client (It was working before)

All data is normally logged (I see all new logs in bOS config in each Data logger, but graphs just won't show in bOS client.  

0

Line break on HTTP Request

Ricardo Pinto | visiontech pt 7 years ago in bOS Configurator / Tasks updated 6 years ago 1

Hi,


I'm using Clickatell SMS API, together with Tasks (Httprequest) to send notifications from Comfortclick system. It's working great, but I'm looking forward to use line breaks in sent text.


Clickatell uses %0a as line break. The problem is that %0 is also used as property values on Comfortclick.


Is there another way to use property values beside %x, or use any kind of delimiter?


Thanks

0
Under review

Z-Wave Bug

Marco Magnani 7 years ago in Devices / Z-Wave updated by ComfortClick Support 7 years ago 3

Dears

every time I open the setting proprieties of eth included Z Wave device I got the following error message:

Image 813


In my case the integrated device used is the Fibaro ZWave plus smoke sensor. Can you fix it please?


Regards


Marco

0

HTTP

Dev Venba 7 years ago in Devices / Http 0

Hi,

We need to do an action wherein when anyone press the bell button on the video intercom, the lock relay ( in z wave ) gets triggered. Please assist !

0

MCO HOME RELAYS

Dev Venba 7 years ago in Devices / Z-Wave 0

MCO home relays are getting added in jigsaw z wave but the issue is with the feedback ( status ). We have used jigsaw z wave and also the UZB stick 


but still no success. The same stick over any other server or computer gives feedback for MCO home relays. Can anyone please comment ?

0

MODBUS WITH PRODUAL HLS 44 Thermostat

Dev Venba 7 years ago in Devices / Modbus 0

I am trying to integrate Modbus Thermostat ( Produal HLS 44 ) with Jigsaw Z wave via RS 485 ( RTU ). The register details are mentioned below :-


Holding Register Address 1 ( 40001 ) = FAN SPEED CONTROL WRITE

Holding Register Address 2 ( 40002 ) = SET POINT WRITE


Input Register Address 18 ( 30018 ) = SET POINT BY USER

Input Register Address 19 ( 30019 ) = FAN CONTROL BY USER




Those Address were verified using MODSCAN 32 and found to be correct.











Now in jigsaw, the scenario is different. The setup was :-




ACTUALLY ADDRESS 18 IS FOR SET POINT BUT  I AM GETTING THE SET POINT IN ADDRESS 17 ( 18 - 1 )

SIMILARLY ADDRESS 19 IS FOR FAN SPEED AND I AM GETTING IN ADDRESS 18 ( 19 - 1)

So what we have seen is for input register, we need to deduct -1 with the address mentioned in datasheet. 







REGARDING THE HOLDING REGISTER 1 AND 2, IT IS NOT WORKING. I AM ABLE TO GET DATA FROM INPUT REGISTER BY DEDUCTING THE ADDRESS BY 1. BUT I AM NOT ABLE TO WRITE ANYTHING IN HOLDING REGISTER. 



ALSO THE VALUE FROM INPUT REGISTER IS LIKE 280, 275, 220. WE NEED THE VALUE LIKE 28, 27.5, 22 ( divided by 10 ). 


CAN YOU PLEASE SUPPORT ?