Josep Gimenez 5 years ago in Devices / Modbus 0

Hello, I have a problem with Modbus wrong reading values. I have a table with the Power from SMA Modbus Device, this values ​​are normaly between -10kw to 10kw but sometimes this value is readed wrong and set to max value of Input Variable, this situation make that the graph visualized wrong, exist the possibility to filter the values?

Thx

0
Under review

bOS configurator stops working whenever i change a value on a Variable.

Manuel Dias Dias 5 years ago in bOS Configurator updated by ComfortClick Support 5 years ago 2

I have been evaluating your solution on my PC , where i have installed your server , and after watching a few videos i add two modbus devices to my project. The problem is whenever i try to change a variable value for simulation at bOS configurator the application stops working and it looses the connection to the local server.

Is this a common problem ?

Regards,


MDias

0

Unable to discover BACNET device

Miguel Paredes 5 years ago in bOS Configurator / Devices updated by Andy Gill 5 years ago 5

Hi, i have a Bacnet Controller conected to my network( T3000 ) and i am unable to discovery it through comfortclick

i am able to find it through the main controller software and through YABE (BACNET Explorer)

tryed connecting the device directly to my PC and disabling all the firewall and still do not work. any other advice??

0
Under review

Unable to add RUN PROGRAM to a scene

Fernando Indopesan 5 years ago in bOS Configurator / Tasks updated by ComfortClick Support 5 years ago 1

Hello! Since the last version (4.7.0) I'm not able to Run a Program from a Scene, I was able in previous versions and it's very useful. I can only set the Enable or Blocked feature, but I can't run it. It'll be pretty helpful, now I have to create a variable just to call the program.

0
Under review

SMA Tripower 10 Modbus communication problem

Josep Gimenez 5 years ago in Devices / Modbus updated by ComfortClick Support 5 years ago 1

Hello, 

I'm trying to connect with a SMA Tripower via Modbus TCP and I can connect with it but when I try to read registers the Tripower response NaN values all the time, I try to change the Slave ID and I try to read diferent adreces but doesn't work, I used the SMA example of the web and I make a new Modbus connection too, can you help me please. Thank you.

0

Did anyone have any success with controlling air conditioning or shutters through Google Home?

Tomasz Michalak 5 years ago in bOS Configurator updated by Gruyère Energie SA 5 years ago 7

Did anyone have any success with controlling air conditioning or shutters through Google Home?

shutter?
air conditioning?
gate?

0
Under review

Qubino integration Problem

Miguel Paredes 5 years ago in Devices / Z-Wave updated by ComfortClick Support 5 years ago 1

I am having problems adding correctly a qubino Flush 1 relay module(ZMNHAD3) it can be added to BOS with no problem, but i can only control the relay and view watts reading. but it will not show binary sensors status and will not show any temperature data ( i have the temperature Sensor already and works find in other controller). also i am having problem to add the parameters manually, everytime i would like to set the parameter it display "index outside the limits of the matrix".

0

Themes: User interface

Paul G 5 years ago in bOS Configurator / Themes updated by anonymous 5 years ago 2

Hi, my themes shows pitch black on the Configurator, however the client shows colour and controls. I tried to add a KNX control, a lamp to the theme. I get the following error "user interface object reference not set to an instance of an object", however the object is shown on the client, but it doe snot show on the configurator.

0

Simple KNX short Long operations

Daniel 5 years ago in Devices / KNX updated 5 years ago 4

for example the shades up/down/step command so the shades keep moving up or down until end or stop command. Can it really on via a program?