Enter forum description here ...
0

Blu Ray Integration

Sneha V 6 years ago in General updated by Pedro Juan Marza 5 years ago 4

Hello,


How can we integrate Sony Blu-Ray Player in Comfort Click?

0

Loxone

Guillem Morey 6 years ago 0

Does anyone has tried to work with Loxone and ComfortClick?


BR

0
Under review

Bug with admin menu

Francois Lesueur 6 years ago in bOS Client updated by ComfortClick Support 6 years ago 4

Hello,

I created a project with 1 theme containing 1 panel containing : 

- 5 simple panels, the 4th one being tagged as "admin only"

- 3 panels containing sub-panels


From the Android or bOS clients, I couldn't access the last sub-panel from the bottom menu. I could access it though from a panel link.


I turned the "admin only" flag off, and I was able to access the last sub-panel. Since I needed to restrict access to this panel, I activated the "pin" feature. So, that's ok, although I would have preferred the panel to disappear completely from the menu. 


Just to let you know this minor bug that you may want to fix. 


Kind regards,

François 

0

licence is recoved

charis vlassakis 6 years ago in General updated by Fabien Fuster 6 years ago 2

Image 1356

0

Send a command twice

Alex K. 6 years ago updated 6 years ago 7

Hello,


I am using a demo installation of comfortclick. I am trying to power on/off a Sony monitor through a global cache device (GC-100-12).

I have built an ir receiver with an arduino.

When I press the power on/off button I get these two commands.


A90
Decoded SONY: A90 (12 bits)
Raw (26): 2400 -600 1200 -600 600 -550 1200 -600 600 -600 1150 -600 600 -600 600 -550 1200 -600 600 -600 550 -600 600 -600 600 
A90
Decoded SONY: A90 (12 bits)
Raw (26): 2400 -600 1200 -550 600 -600 1200 -600 600 -550 1200 -600 600 -550 600 -600 1200 -600 600 -550 600 -600 600 -600 600 


From what I see it is the same command send twice, I guess to avoid false positives.

I have configured the command to comfortclick and I can send the command, this is what I get when I receive the command with my ir receiver.


A90
Decoded SONY: A90 (12 bits)
Raw (26): 2400 -550 1250 -500 650 -550 1200 -550 650 -550 1200 -550 600 -600 650 -500 1250 -500 650 -550 650 -550 650 -550 600 


The problem is that the monitor doesn't power up.

I think I need to send the command twice to power it up.

How can I achieve this through comfortclick?

0

Index was outside the bounds of the array

Francois Lesueur 6 years ago in Devices / Z-Wave updated 6 years ago 2

Hello,


I'm using old Fibaro Z-Wave modules. They are included into the Z-Wave controller without any issues, but the parameters are not populated automatically. So, I have to add them manually. 


Sometimes, this is working fine ; some other times, I'm getting the "Index was outside the bounds of the array" message when I'm trying to set a parameter. (Reading parameters work fine.)


Example with a Fibaro FGS221 for which I added parameter 14 only (switch type) ; I can't modify this parameter, which is quite a problem as it means that I cannot control correctly the relay with the switch.


Thank you for your help,

François 


0
Under review

bOS configurator bug

Marco Magnani 6 years ago in bOS Configurator updated by ComfortClick Support 6 years ago 1

Dear support,

I see the following bug: in the bOS configurator I have the following enum descriptions: Scheduler, Manual and Sensor.


Image 1350


Instead when I use the App on my iPhone in the selection menu I see Auto, Manual and Sensor.


Image 1351


Even I rename the Scheduler in the bOS configurator in the App client the name doesn’t  change (the system keeps the first name that I assigned: Auto)

Can you fix it, please?


Marco

0
Under review

Very slow reading / writing + timeout errors with WEINZIERL BAOS 771

Ricardo Pinto | visiontech pt 6 years ago in bOS Server updated 5 years ago 12

Hi,


I've been using a temporary JUNG IPS 100 REG IP interface on bOS, and it was working fine.


But I had to change that temporary IP interface for a BAOS 771 from WEINZIERL.


As you may know, BAOS actually let's you use IP tunneling for programming / visualization, and also to use it as Bus Access Object Server, for prototyping, third party integration etc.


As soon as I started using the BAOS with bOS, I've noticed that bOS is extremely slow reading / writing.


In fact, when the KNX connection becomes true, bOS tries to read every feedback and it shows "No response to read from..." in every address. While this happens, I can see on ETS bOS trying to read the feedbacks almost with a 2 to 3 second delay between them.


If I run a scene for example, it tries to execute the scene at the same very slow speed, 2 to 3 seconds in every group address of the scene.


If using the BAOS on ETS for programming, it works at a "regular" read / write speed.


If using the BAOS with the internal DPT server, it works fast at reading / writing.


If I use it on bOS and click in two or three lights very quick for example, it turns the first one, 2 to 3 seconds and turns the next one, and so one.


I know that BAOS 771 is "old" and with a 10BaseT ethernet connection, but it's a very strange behavior.


Ant tips on that?


Best regards

0

Acceptance of server's public keys

Michael Kanellias 6 years ago in bOS Client 0

Hi. A client of mine, who bought the license, keeps getting in his iPhone the message : "Do you accept server's public keys" when he connects to bOS Client. What is this?

0
Under review

Nodes

Guillem Morey 6 years ago in bOS Server updated 6 years ago 2

Just as information, is there any limit of nodes ?