I am currently unable to reboot my Colibri Z-Wave servers.

APP MOD 1 year ago in bOS Server updated by ComfortClick Support 1 year ago 1

Hello,

I am currently unable to reboot my Colibri Z-Wave servers. The only way to fix this is to power cycle them. Do you have any solutions for this problem?

0

No response: Read 1/2/1 Devices\KNX\Ground

Sebastian Goff 1 year ago in Devices / KNX updated by Jürgen Jürgenson 1 year ago 1

Hello, all, I’ve got an issue where the integriti Alarm within a building. When turned off it has an output that then goes to an input of Knx which then operates outputs through the Knx. I am using a comfort click controller and for some reason I’m getting this error, but it only happens once and after attempting to arm disarm after the first time it works fine anyone got any ideas what would cause this?

Devices\KNX\Ground Floor|Ground Floor Security|Ground Floor Alarm on/off

26/02/2024 7:10 AM

No response: Read 1/2/1 Devices\KNX\Ground Floor\Ground Floor Security\Ground Floor Alarm on/off.



0
Under review

4.10.9 Update issue

Kristián Vojčík 1 year ago in bOS Configurator updated by ComfortClick Support 1 year ago 1

Hello.

I noticed that I have issue with updating to 4.10.9 from 4.9.40. When I try to connect to Jisgaw I got popup that I need update but update button is blank and without updating I cannot connect and no dowload config doesnt do anything it just close config program. Please help me to get around this I cannot reach most of my configs. 

Image 4837

0

Controlling Daikin VRV central air conditioning system via DTA116A51 board with Modbus protocol.

APP MOD 1 year ago in Devices / Modbus updated by Jürgen Jürgenson 1 month ago 4

Hello everyone,

I am currently trying to connect and control a Daikin VRV central air conditioning system via the DTA116A51 board using the Modbus protocol. However, I am unable to read or write 3 or 8 bits... from the 16-bit Holding Register or Input Register to bOS. Do you have any solutions to this problem? Please help me.

D3NET-Modbus+Communication+adaptor_Function....pdf


Image 4831

Image 4834


0

Problems with square brackets on a URL (Dahua TiOC API)

Ricardo Pinto | visiontech pt 1 year ago in bOS Configurator / Devices updated 1 year ago 13

Hello!

I've recently testing out TiOC cameras from Dahua, where I need to use their TiOC API. I've tested some of the URLs on the browser, and with curl, and even though they work, I have a small problem with bOS.

The url itself is this one (just for now):


http://192.168.1.108/cgi-bin/coaxialControlIO.cgi?action=control&channel=1&info[0].Type=1&info[0].IO=1

On the browser, I just have to past the url, enter the username and password and that's it. Testing done.

With curl, as I have square brackets, either I use the --globoff option or I have to change the [ ] with %5B and %5D respectively. Otherwise the curl command gives error.

So, I'm trying to use this url on bOS and it simply doesn't work.


If I use the [ ] I don't get anything. If I use the %, it will conflict in the string editor, as %5... will expect the pointer. I've tried almost everything I can remember, 

I know some guy that will probably figure this out, as I know that he probably uses TiOC cameras...


Yes Jürgen, this message is for you :P

Help!

Best regards

0

huawei Inverters

Mihai Berindei 1 year ago in bOS Configurator / Devices updated by Jürgen Jürgenson 1 year ago 1

Hello all,

Did someone do an integration of Huawei inverter with smartlogger Modbus TCP?

Thank you!

0

Visualization

István Gehl 1 year ago in General updated 1 year ago 5

I set images for the buttons in the visualization. By default, the silhouette of the images is visible and they become black when turned on, this works everywhere.

I changed this to default to black. But there is a button where, when turned on, the silhouette appears as I wanted, and there is one where it does not change, it remains the same black.

Why is this so?

0

Error not reconnect Modbus TCP.

APP MOD 1 year ago in Devices / Modbus 0

I am currently experiencing an issue where the Modbus TCP connection does not automatically reconnect after being disconnected. The bOS still shows the status as "true", but I have to manually enable and disable it to get it to work again. This error occurred after I updated the bOS server to version 4.10.8. Is there any way to fix this?

0

Conter Log calculations

Simen Hagen 1 year ago in bOS Configurator / Tasks 0

Hi, I wonder if there is a bug or delay or something in calculating the values with Conter Log. Why is ¨This month count'' showing 140,7 when ''Previous Month count'' and ''Total Value'' is 161,7 and 17,7?

161,7 - 17,7 = 144, not 140,7

If I use the last value in the Log which is 160,8 or the value at 23:00 it doesn't make sense either. 

Or am i missing something here?


Image 4813

Image 4816

Image 4817

Image 4819

Regards
0
Under review

New alert notification - issues with paragraphs

Ricardo Pinto | visiontech pt 1 year ago in General updated by Noel Fuentes 1 year ago 10

Hello,

The new alert, doesn't assume any new paragraphs on e-mails. Instead, it just writes the text on the same sentence. It doesn't assume paragraphs on the e-mails, but it assumes of the push notification and on the log :/

Image 4808

Image 4809

Image 4810


I had to use html tag <br> to be able to have paragraphs on the e-mail body. Which in turn, sucks on the push notification as it shows as <br>


Image 4811

Image 4812

Best regards