After update 4.10.3

D D 1 year ago in Devices / Cameras updated by ComfortClick Support 12 months ago 11

The cameras stopped working on application for mobile phone after update.

Is there any solution for that?

0

Satel: status value of partition

Andrzej Szymkowicz 1 year ago in bOS Configurator / Devices updated by Ricardo Pinto | visiontech pt 1 year ago 3

Satel status value of partition shows numeric values (index) instead of text statuses. Can you provide list of number statuses corresponding to text statuses and/or better change this function in bOS?

0
Under review

license users number colibri

IVAN ROSINI 1 year ago in bOS Server updated by ComfortClick Support 1 year ago 1

On Colibri there is 2 user or 1 on license?

because on manual say 1 user on website say 2 users

thanks

0
Under review

Denon Heos groups - issue

Joost vB 1 year ago in Devices / Other updated by István Gehl 2 weeks ago 22

Since the latest updates on bOS and Denon HEOS there seems to be an issue with forming/keeping groups of speakers.

The Denon node did work as expected, but since the update it tries to control the group. But by doing so it disassembles the existing group, or (if the group’s not there yet) will fail to combine the speakers into a group.

Anyone experiencing the same behavior?


By the way:

Denon is having another problem, it’s losing its favorites all the time. I’ve contacted Denon support for that.

0

Can Login via bOS client but can not login via bOS Configurator

Marek Dobosz 1 year ago in bOS Configurator updated by Ricardo Pinto | visiontech pt 1 year ago 1

Hi

I have Jigsaw v2 and device is registered.

The problem is that I can connect to CC using bOS Client but I can not loging to CC via bOS Configurator

Looks that after setting credential (user and password - the same when login via Client) the initial page is refreshing and again asking for credentials.

- PC is in the same network as CC

- CC is registered in cloud

- no matter if used Manual Configuration or not

Checked connection via Wireshark and it seems that connection between PC and server is done correctly.

Any idea?

0

ReadMProp failed ETS6

Kristián Vojčík 1 year ago in Devices / KNX 0

Hello.

I am getting this issue ReadMProp failed with Jigsaw version 1 and ETS 6 when trying program KNX over local network but diagnostic is working. Is there some fix for it?

0
Under review

update 4.10.3 after

István Gehl 1 year ago in bOS Configurator updated by D D 1 year ago 6

Image 4765

0

Different Layout Orientation

Bros Knx 1 year ago in bOS Client updated 1 year ago 2

Hello everyone.

I have a problem to which I have not found a solution by browsing the forum and it may be very simple but I have not been able to find it.

In a Free type panel I have inserted a layout to insert controls, but I notice that if I see it in the Windows client it has a different orientation than if it is seen in an Android client. I attach a photo so you can check it.

Is it possible to avoid this? At this time it is impossible to locate any controls precisely.

Image 4761

0

Http digest authentication

Valentin Popa 1 year ago in Devices / Http updated by Jürgen Jürgenson 1 year ago 3

I try to connect to Hikvision doorbell using http and authentication is Digest Auth. I connect successfully from Postman but not using http from confortclick. Any idea if http suport digest auth and how to do it?  

0

Extraction follows the energy consumption

Dan Sharpe 1 year ago in Devices / KNX updated by Jürgen Jürgenson 1 year ago 1

Hello

I have a KNX energy meter in front of a stove, and there is a 0-10V KNX regulation in front of the air extractor, which is already controlled, by percentage from 0-100%.

Energy, DPT type = 14.031

0-100%, DPT type = 5.001

With a consumption on the stove of, for example 300W, the air extraction level should be set to 15%.
At 500W, the level should be set to 25%.
At 1000W, the level should be set to 45%.

The stove's heating element, is switched on and off at a fixed time interval, and the interval becomes smaller, as the stove is regulated to a higher level, and the consumption is getting higher.
After all, the air extraction must remain constant, as long as the consumption is, for example between 300 and 500W.
When the stove is switched off (less than 0.10W), the extraction is desired to continue at 15W for 5 minutes.