Enter forum description here ...
0

command HTTP GET

marco 1 year ago in Devices / Http updated 1 year ago 7
Good morning, 
I have an NVR video recorder that can send HTTP GET commands. I would like to send commands 
to Comfortclick to turn on devices based on camera detection.
the commands that NVR can send are of the type:
http://ip address:port/saia-irc/alarm_send?open_door

where open_door I added it

However, I cannot connect it with Comforclick, via RPC

Can anyone help me?

A thousand thanks
0
Under review

Is it possible to run an inverted scene?

Pavlos Laskas 1 year ago updated by Ricardo Pinto | visiontech pt 1 year ago 3

I run comfortclick configured scenes with the press of a KNX button. It would be handy if I could run the same scene inverted (to turn off the specific lights for example)

0
Under review

I am currently unable to reboot my Colibri Z-Wave servers.

APP MOD 2 years ago in bOS Server updated by ComfortClick Support 2 years ago 1

Hello,

I am currently unable to reboot my Colibri Z-Wave servers. The only way to fix this is to power cycle them. Do you have any solutions for this problem?

0

No response: Read 1/2/1 Devices\KNX\Ground

Sebastian Goff 2 years ago in Devices / KNX updated by Jürgen Jürgenson 2 years ago 1

Hello, all, I’ve got an issue where the integriti Alarm within a building. When turned off it has an output that then goes to an input of Knx which then operates outputs through the Knx. I am using a comfort click controller and for some reason I’m getting this error, but it only happens once and after attempting to arm disarm after the first time it works fine anyone got any ideas what would cause this?

Devices\KNX\Ground Floor|Ground Floor Security|Ground Floor Alarm on/off

26/02/2024 7:10 AM

No response: Read 1/2/1 Devices\KNX\Ground Floor\Ground Floor Security\Ground Floor Alarm on/off.



0
Under review

4.10.9 Update issue

Kristián Vojčík 2 years ago in bOS Configurator updated by ComfortClick Support 2 years ago 1

Hello.

I noticed that I have issue with updating to 4.10.9 from 4.9.40. When I try to connect to Jisgaw I got popup that I need update but update button is blank and without updating I cannot connect and no dowload config doesnt do anything it just close config program. Please help me to get around this I cannot reach most of my configs. 

Image 4837

0

Controlling Daikin VRV central air conditioning system via DTA116A51 board with Modbus protocol.

APP MOD 2 years ago in Devices / Modbus updated by Jürgen Jürgenson 6 months ago 4

Hello everyone,

I am currently trying to connect and control a Daikin VRV central air conditioning system via the DTA116A51 board using the Modbus protocol. However, I am unable to read or write 3 or 8 bits... from the 16-bit Holding Register or Input Register to bOS. Do you have any solutions to this problem? Please help me.

D3NET-Modbus+Communication+adaptor_Function....pdf


Image 4831

Image 4834


0

Problems with square brackets on a URL (Dahua TiOC API)

Ricardo Pinto | visiontech pt 2 years ago in bOS Configurator / Devices updated 2 years ago 13

Hello!

I've recently testing out TiOC cameras from Dahua, where I need to use their TiOC API. I've tested some of the URLs on the browser, and with curl, and even though they work, I have a small problem with bOS.

The url itself is this one (just for now):


http://192.168.1.108/cgi-bin/coaxialControlIO.cgi?action=control&channel=1&info[0].Type=1&info[0].IO=1

On the browser, I just have to past the url, enter the username and password and that's it. Testing done.

With curl, as I have square brackets, either I use the --globoff option or I have to change the [ ] with %5B and %5D respectively. Otherwise the curl command gives error.

So, I'm trying to use this url on bOS and it simply doesn't work.


If I use the [ ] I don't get anything. If I use the %, it will conflict in the string editor, as %5... will expect the pointer. I've tried almost everything I can remember, 

I know some guy that will probably figure this out, as I know that he probably uses TiOC cameras...


Yes Jürgen, this message is for you :P

Help!

Best regards

0

huawei Inverters

Mihai Berindei 2 years ago in bOS Configurator / Devices updated by Jürgen Jürgenson 2 years ago 1

Hello all,

Did someone do an integration of Huawei inverter with smartlogger Modbus TCP?

Thank you!

0

Visualization

István Gehl 2 years ago in General updated 2 years ago 5

I set images for the buttons in the visualization. By default, the silhouette of the images is visible and they become black when turned on, this works everywhere.

I changed this to default to black. But there is a button where, when turned on, the silhouette appears as I wanted, and there is one where it does not change, it remains the same black.

Why is this so?

0

Error not reconnect Modbus TCP.

APP MOD 2 years ago in Devices / Modbus 0

I am currently experiencing an issue where the Modbus TCP connection does not automatically reconnect after being disconnected. The bOS still shows the status as "true", but I have to manually enable and disable it to get it to work again. This error occurred after I updated the bOS server to version 4.10.8. Is there any way to fix this?