Error launching client after transfering the project to a new Computer
Hello,
I restored and old configuration made with other computer to a new computer and everything seems to be ok.
But when I launch the Client I get the following error:
"Can not connect with this profile. Profile key does not match
the server key. Possible security violation. "
I re-instaled everything and deleted everything but I still cannot launch the Client.
I have also removed the controller from my account in order to add it again.
Could you help ?
Thank you

Import 3 byte KNX value
I´m trying to import a 3 byte status value that needs to be put through the bit converter. Altough the only option I find is to import it as a date or time value. How do I add it as a generic 3byte value?

Use Thermostat Task and Change Setpoint with a KNX Value
I´m trying to use Thermostat Task but I would like to Change Setpoint Temperatura with a KNX Value, is it possible?
Thank´s to All

z-wave node description shows script error message
Hi
Clicking on the z-wave "Node Settings" button for a device in Devices\Z-Wave brings up the script error message shown below.
This happens for all z-wave devices. I'm running bOS on a Jigsaw device, configurator on Windows 7 and all are fully up to date with latest ComfortClick releases. I can access and browse the internet from my PC. Can you help please?

Trying to integrate jigsaw with knx
Hai I am trying to integrate knx with jigsaw I am not using any knx IP interface.connection type as jigsaw whether I need to purchase any Ip interface or without Ip interface can do it.

I am not sure how to configure http > Boolean with url /api
I am not sure how to configure http > Boolean with below url /api
I have to pass l1498904289859 to open window http://192.168.2.109:8080/send?deviceMac=b4430dd11511&codeId=l1498904289859 Close window l1498900850560 http://192.168.2.109:8080/send?deviceMac=b4430dd11511&codeId=l1498900850560
using browser to enter url its working and programme > set the http request also work

Modbus new function
Dears
I see that in one of the last BOS version in the ModBus device has been introduced two new configuration settings: Read Function Type and Write Function Type.
I want to understand more how those 2 setting work: which address are written or read at once instead separately (if I select write or read multi)? This is not clear to me… If we suppose to get only 1 modbus device connected with slave address 1 and it contains many address for eg 10, 11, 13, 20, 21, 25 and 110 (all are coils). Is the Bos software going to write or read once all the address from 10 to 110? From the time point of view instead? If the read interval (in the BOS Modbus confi g page) is 100 ms, does it mean that Bos software will read or write all the previous address data (10, 11, …, 110) in 100 ms (instead taking 100 ms each as was before)?
Regards
Marco