GSM Router
I use a modem Router LTE in my LAN to be connected to Internet and to make and receive mobile calls with my smartphone.
I would like to integrate it to my Grinder Black and use it like a GSM Modem, but I haven´t any COM port to configure. How I could do it?
Thanks.
change modbus setting through formula
Today my home has had a power outage.
My solar inverters are connected to my Jigsaw through modbus. It appears the modbus connection isn't restored after the outage, possibly because the inverers restart shortly after the Jigsaw-modbus is activated.
The solution seems to be to deactivate and reactivate the modbus through bOS (settings > driver > enable > false/true).
I'm now trying to make a fomula which is triggered after a reboot of bOS. The formula should deactivate and reactivate the modbus driver.
Any tips on how to deactivate and reactivate the modbus?
Or are there any other ways to reactivate the modbus connection?
Thanks for your support!
Sonos speaker won't communicate with CC after losing power.
Hello, I have noticed that somewhat randomly my Sonos integration would stop responding. I have one Arc speaker which works well with ComfortClick when I set it up, however when the speaker (or whole house) loses power ComfortClick will no longer update speaker status and won't respond to called functions.
It works again after I either remove the speaker from bOS Configurator and add it again, or which I found out recently - after turning the Driver-Enabled to False and True again.
Why is that happening and how to fix this? Enabled value cannot be changed from script.
Can't import password protected knxproj
After hitting 'Import data from ETS' and selecting the .knxproj file, nothing happens if the file is password protected. Non password protected files are loaded.
Server & config version: 4.9.36
Modbus 32int variable to KNX address
Hi,
I need to export a modbus variable (Integer 32 bit signed) to KNX address.
Unfortunately none of 4 byte KNX objects (signed, unsigned, float) can be link to that modbus variable. Have you any suggestion please?
Thanks.
Direct Connection to KNX IP Backbone
Hello,
I have a KNX installation with an IP backbone and 4 areas connected via IP routers. Currently, the BOS server is connected to one of the routers using the connection type 'KNX IP'.
In order for status messages, etc. from the other areas to reach the server, I have created a dummy object there in the ETS. Unfortunately, this slows things down considerably, as all commands pass through the area.
Is it possible to directly integrate the server into the IP backbone? I suspect that this might be achievable through the ConnectionType 'KNXnet/IP Routing (Falcon)'. Unfortunately, I haven't been able to establish a connection through this without guidance. Do I perhaps need to set up something like a dummy router in the ETS? Regrettably, I haven't come across any instructions or tutorials on this topic.
JSON parsing
I created a TcpServer with a JSON parser:
I added a string parser with a token :
I use Postman and send :
{"TestData":{"Data1":"1"}}
ComfortClick receives data:
POST / HTTP/1.1
Content-Type: text/plain
User-Agent: PostmanRuntime/7.32.3
Accept: */*
Postman-Token: e79d7b2e-8a0a-4ef6-bd47-8d5cc7e8c6f3
Host: 192.168.1.7:16900
Accept-Encoding: gzip, deflate, br
Connection: keep-alive
Content-Length: 26
{"TestData":{"Data1":"1"}}
But the parser throws an error:
Devices : 15.08.2023 14:54:09 : Error : Devices\Test\String : Error parsing received data. Unexpected character encountered while parsing value: P. Path , line 0, position 0. w Newtonsoft.Json.JsonTextReader.ParseValue()
w Newtonsoft.Json.Linq.JObject.Load(JsonReader reader, JsonLoadSettings settings)
w Newtonsoft.Json.Linq.JObject.Parse(String json, JsonLoadSettings settings)
w ComfortClick.Tasks.Common.ReceiverBase.OnDataReceived(String data)
It looks like the header is being passed to the parser, not the JSON itself.
Bug or my configuration error?
How to disable header passing to parser?
Tested on ComfortClick v 4.9.36
How to do Z-wave diagnostics
My field is like this Aeotec nano switch is not deployed in every room. In the rooms circled in red, there are two Nano switches and one Multi sensor on the ceiling of each room. There will be a few empty rooms in between. According to the current test, the Z-wave network is not very smooth, and the device is often in the Waiting state. I would like to ask if there is any way or detector to diagnose the quality of Z-wave network! ?
Integration with Roomba iRobot
Hello,
Wouldn't it be nice, since a lot of people are using vacuum cleaner robots, to integrate it in CC?