Johnson Controls vent unit
Hello,
Does anyone manage Johnson Controls ventilation unit via Bacnet? Does it work good or bad?
Our customer wants to manage Johnson Controls huge ventilation station in offices and ventilation controllers are Johnson Controls IOM and Johnson Controls FEC. As I understood, we have to connect IOM controllers via cat6 cable and connect it via bacnet in bos configurator, then I have to find which addresses has managing functions.
Maybe I have to connect it other way?
Will be thankful for any advise.
Regards,
Artjom
How to
I have 2 variables Double (setpoints) A and B. When I change the value in one I want the following rule. A can´t be smaller than B and B can´t be bigger than A . Any ideas?
Bticino Myhome
Hi, I have already seen in the description that it works for the F454 but, please, could you confirm whether or not it is compatible with the Bticino F453 server? I have a client with this model, I have made several tests and there is no way it works and I don't know if I am doing something wrong or if it is simply not compatible.
Thanks for your help. Regards
Pablo
Modbus read value problem
Dear
I am working on an energy measurement project for a customer, in which I intend to implement Comfortclick/bOS as the management system.
I have established a modbus connection between an energy measurement device from Finder and the bOS. I simultaneously noticed that the measurement (voltage, current and power) shown on the Finder display differs from the reading obtained by the bOS which is slightly higher.
Settings:
Connection Type: Serial
Serial Transmission Mode: RTU
Low Word First: False
Low Byte First: False
Data Format: LittleEndian
Write Function Type: WriteSingle
Read Function Type: ReadSingle
Modbus Table: InputRegisters
Data Format: Signed32Bit (to power) and Unsigned32Bit (to voltage and current)
Scale Factor: 1
Use Status Address: False
Readcyclically: True
Please, could you help me with the configuration in order to get the correct reading?
Thanks,
Eduardo
ip relay
Hello,
I would like to control a Web Relay (Controlbyweb) from Jigsaw.
which device should I use?
relay ip address: 10.10.10.84
login: admin
pw : password
on command: http://10.10.10.84/state.xml?relay1State=1
off command: http://10.10.10.84/state.xml?relay1State=0
Thanks for your help
How to read KNX group values form bOS server
Hi,
Its it possibe to read group value from bOS server. :E.g: "GroupValueRead" sent from KNX network and then get response "GroupValueResponse" from bOS?
I tried to change "Read" flag to "TRUE" under Commuunication section but bOS is still not responding to "GroupValueRead"
Elering example library
Have anyone tried elering v2 from the examples library?
I don´t get any prices and I don´t know what I am doing wrong.
Jigsaw KNX - Error connecting to device. No ACK
I've seen some similar posts, but no one regarding KNX connection. I do have problems to connect through Jigsaw KNX and every few seconds I get this error. Does anyone know how can it be solved? Thank you in advance
Shelly 3EM 3-phase energy meter integration
Hi.
Did anybody have integrated Shelly 3EM to comfortclick?
Thank you.
Somfy API Integration
Hi to all,
I need help to use HTTP to setup API Integration for Somfy.
Any suggestion? i always get Unauthorized
I'm trying to use this guide: Somfy API Developers but without success.