Enter forum description here ...
0

http read intiger value from response result

imperialbms 2 years ago in Devices / Http updated by Ricardo Pinto | visiontech pt 2 years ago 2

hello, how to read intiger value from response result?

Image 4517

0
Under review

KNX Remote Programming through Jigsaw

Fatlum Telaku 2 years ago in Devices / KNX updated by ComfortClick Support 12 months ago 5

In the new version of bOS configurator(4.9.23) there is the option for "KNX Remote Programming", which from what I understood means that we don't need a forwarded port because we can program our KNX devices remotely only through Jigsaw normally with a provided gateway.
I have tried it many times and the problem is sometimes it works and other times it doesn't. So, my question is, is this feature on testing phases or am I configuring anything wrong. To be specific most of the times it just shows the "Disconnected" sign, like in the picture attached.

Thanks in advance.

Image 4514

0

Speak Text stops working

Nathan Meinck 2 years ago in bOS Configurator updated by Ricardo Pinto | visiontech pt 2 years ago 2

The Speak Text function stops working, restarting the service monitor doesn't help, system reboot doesn't fix it. A cold reboot of the Jigsaw sometimes fixes it but not consistently.

It's been running for 6 months, and it has only just started playing up, probably for 1 month.

Any assistance would be greatly appreciated.

0
Under review

homeconnect

Matteo Cavatorta 2 years ago in Devices / Other updated by Stephen Andries 2 years ago 3

Hello,

anyone know how to integrate Home Connect devices?

Thanks

0

KNX Scenes Control Template

Pedro Jorge 2 years ago in Devices / KNX updated by Ricardo Pinto | visiontech pt 2 years ago 3

Hello 

I do see that we have a Device 018.000 Scene Control to activate and learn KNX scenes 

I was woundering what  the best pratice would be for import this Group addresses and setup a template to call and learn them from the Interface 

Thanks for the help in advance 

0

2N IP Solo Integration

Michele Calzolani 2 years ago in Devices / Other updated by Jürgen Jürgenson 2 years ago 6

Hi guys,
is there anyone already integrated 2N Ip Solo with Comfort Click?

0

HUE - node supported use of motion sensors, remotes and scenes

Joost vB 2 years ago in bOS Configurator updated by Ricardo Pinto | visiontech pt 2 years ago 1

Hi,

after linking my HUE setup to bOS I find my lights, groups and smart sockets. Those work as expected, so all good on that aspect.


Within my HUE setup I have some motion sensors, also a few remotes and I use HUE scenes. The node doesn’t seem to have native support for those.


I’ve found some topics covering the use of motion sensors and scenes, but the somewhat fragile/complex solutions using API or IFTTT. 


My question:

Will there be a node update which will integrate the use of motion sensors, remotes and/or scenes in the (near) future?

0
Under review

Basic Device - Serial Connection - Received Data structured in a better format

Calin Birtocean 2 years ago in Devices / Basic updated by ComfortClick Support 2 years ago 2

Hi,

I have a meter connected serial to bOS. I am looking to find a way to structure the received data so I can interpret it in bOS and display it. For example highlighted in yellow below the data 30 30 30 30 30 30 30 31 30 30 31 35 would be the meter number 10015. The 30 represents a 0, 31 represents a 1, 32 represents a 2, etc

Here is a part from the meter datasheet:

Image 4489


Here is the way the meter connection is configured in bOS as Basic Device:

Image 4490

 

Here is the command for the request string:

Image 4491

Same command with different data type:

Image 4492


Both the above commands return the same data:

Image 4497

Image 4496

As seen the command is sent and data is received. The challenge I have is that the value left in the string variable created doesn't contain the full string 

Image 4499

This would be the data displayed using their software:

Image 4500

Any tips on how this can be handled in bOS so when receiving the data it can be structured in such a way so when extracting the 30 30 30 30 30 30 30 31 30 30 31 35  it can be used as being the value for meter number 10015.

Thank you, 

Calin

0
Under review

IP camera online vs connected?

alexandros toufexis 2 years ago in Devices / Cameras updated 2 years ago 6

Hello,

What is the difference between the IPcameras' values "Connected" and "Online"?

If the camera is connected and streaming both values are "True". However, when I unplug the camera, the values do not change to "False". They status changes to "False" only when I disable the camera from the bOS configurator.

Is there a way to know the actual status of the camera?

Thank you in advance.

Image 4479

0
Under review

Weather forecast

Dávid Kirchhofer 2 years ago in Devices / Http updated by ComfortClick Support 2 years ago 1

Hello!

Someone can get me instructions or an example how to set up weather forecast based on openweather or any other method?

I'm a little begginer about the bos, and this (https://www.comfortclick.com/BOS/KnowledgeBase/Weather) example cant get me on.

Thank you!

Regards, David