Enter forum description here ...
0

Integration Comfortclick-Sonos-Doorbird

Eloy Larrañaga 2 years ago in Devices / Sonos updated 1 year ago 1

Good Morning.

How can I integrate my sonos devices to reproduce a Doorbird call in Comfortclick?

0
Under review

Token Name for shelly device

Miguel Paredes 2 years ago in bOS Configurator / Devices updated by Ricardo Pinto | visiontech pt 2 years ago 4

hi where can i the Token  Name for shelly devices

im trying to read the temperature using a interger device as is showed in the mqtt video for BOS

but i do not know what is the token name to write.

Image 3920

Image 3921

0
Under review

Berker KNX BIQ switch and ''Thermostat'' Library example

Simen Hagen 2 years ago in bOS Configurator / Tasks updated 2 years ago 10

Does anyone know if a change in setpoint performed with the physical switch affect the setpoint in bOS.

In other words, can you change setpoint with both? KNX physical switch and bOS? And it will sync. automatically? 

Image 3904

Regards

0

Shelly & TCP listener

Krzysztof Szczepański 2 years ago in Devices / Basic updated 9 months ago 1

I have a little problem integrating Shelly through the tcp server

Shelly integration is in your libraries https://www.comfortclick.com/BOS/Library/Devices/115

Everything works fine except the listener.

The listener is configured as a tcp server, accepts connections but does not respond and does not close the session which causes Shelly to hang.

Shelly expects any response from the host or session closure.

I did the tests using https://docs.microsoft.com/pl-pl/dotnet/api/system.net.sockets.tcplistener?view=net-6.0

If the listener answers the call from Shelly or closes the session, everything works fine.

Conversely, when the host accepts the call and nothing returns or closes the session, Shelly stops sending calls to the host and suspends Shelly until a reset. Shelly appears to be waiting for any information from the host, without it being able to complete the routine.

In the code from the MS website from lines 45 to 63 there is a procedure that sends back to the client what the client sent, while on line 64 the connection is closed.

Removing these lines causes the problem and probably simulates comfortclicka operation.

Is there any call that will get a reply from comfortclick's website eg http://192.168.1.10/comfortclickreply?par=1?

Alternatively, you could add a checkbox as an option - "Send this message as confirmation:", "message" ?

checked on bOS v4.9.8 and Shelly 1 with fw 20220209-092750 / v1.11.8-g8c7bb8d

0

Bad communication between Jigsaw and MIM-B19N (MODBUS SAMSUNG)

Jose Jiménez 2 years ago in Devices / Modbus updated by Costel Miron 1 year ago 4

Hi everyone,

i have a jigsaw connected to a Modbus interface module MIM-B19N Samsung. I have the next parameters:

Image 3875

I attach the datasheet of this module to compare if you need:  Manual Interface MODBUS Maquinas clima Samsung.pdf


The question is that some times, randomly, the communication breaks down and we can control any of indoor units we have. In addition, i attach a screenshot of Jigsaw's logs:


Image 3877

I don't know if the problem is because of driver's parameters or firmware error. I will appreciate any help .

Thanks

0

iOS client cannot connect anymore

Francois Lesueur 2 years ago in bOS Client updated by ComfortClick ComfortClick 2 years ago 2

Hello, 

My bOS client can't connect anymore.

I rebooted the iPad, the server, I deleted the iPad from the server. I tried with another Wifi network.

I wanted to delete the profile and add it again : I can't add the profile anymore. It's hanging, and then a "back" button is displayed. 

The problem is still there. 

It appeared all of a sudden on 3 iPads ; none of them can connect anymore.

Server Jigsaw 4.7.0 ; bOS on iOS 9 (old iPad ; can't upgrade to latest iOS version)

What is very strange is : 

- it was working before, and I didn't make any changes on the system

- it's working remotely from a recent iPad 

Do you have any ideas where it could come from ? 

Any ways to help to analyze what is happening when the client cannot connect ? There are no meaningful error message displayed. 

Thanks, 

François 

0
Under review

login error

Francois Lesueur 2 years ago in bOS Server updated 1 year ago 4

Hello, 

I'm getting a "Login error. Please verify your username and password" on my server which I was able to access yesterday. 

I tried with 2 different users, and I tried from bOS client and from bOS configurator : same result. 

Of course, I haven't modified any user name / password. 

Any ideas where that could come from ? 

I don't currently have access to the server, Grinder, as I'm not on site.  I was wondering whether this could come from Windows as I know sometimes it's doing weird updates ? 

I don't have any issues on my other servers, Linux based (Jigsaws)

Regards, 

François 

0

LG TV Integration (ON/OFF)

Nathan Meinck 2 years ago in bOS Configurator / Devices updated by Grzegorz Kulinski 2 years ago 4

I'm using the LG TV Device in CC on a 2021 LG TV (webOS 6). There doesn't seem to be a Power On / Off function. From what I gather the TV is disconnected from the network when powered off (via remote - standby? I would have thought standby would have kept connection with the router). Is there a way around this? i.e. through TV settings? As it's pretty annoying telling a client that they have to power up the TV via remote first before automations will start.

Love to know what people have done in this space, I really don't want to add a IR sprayer to the mix just to turn off and on.

Cheers

0

Mail when public IP change

Jose Jiménez 2 years ago in General updated by Oti Dénia 2 years ago 4

Hi everyone,

i would like to know if it's possible to receive a mail when the public IP of my installation changes.

Thank you 

0
Under review

Access id does not resolve

Bros Knx 2 years ago in bOS Configurator updated 2 years ago 2

Hello everyone.

Unfortunately I have clients that due to server hardware reasons cannot upgrade beyond version 4.8.20. For this I have to use older configurators every time I need to make a change in these servers.

The problem I have is that when I give the Access ID corresponding to this server, the application does not resolve it and returns the Access ID not found message.

Image 3861



However when using versions later than 4.8.20 I have no problem creating the connection.

I also have no problems with the App Client.

Has access to older versions been restricted to the way of creating connections with the Access ID as it has been done until now?