Can we ask is device is OK or online?
Hello everyone
Is there any possibility to make the Comfort Click check the online status of the elements of the KNX bus?
heartbeat?

Colibri showing error to connect server
Newly installed bOS configurator and connected to Colibri. When i enter the access ID and kept username & password default, but its showing error to connect server.

Connecting to KNX
Hi I'm having trouble connecting to KNX devises. I'm using Jigsaw, created a KNX devise and set Connection Type 'Jigsaw', enabled the devise and it says connected.
Successfully imported the ETS file, the devise 'Hall Light' says not connected.
Any guidance / pointers would be much appreciated?

Doorbird
I need to be able to receive the video door entry call in comfortclick.
How can I send such a call to a sonos?
I'm using comfortclick library file for this case. I supose the way is here but I'm unable to configurate it.

how to connect modbus analyzer 4 wire to a comfort click modbus dongle 2 wire?
I need to integrate the measures of a Carlo Gavazzi WM12, but this has 4 wire connection.
Can you help me?
Thanks in advance.

Integration Comfortclick-Sonos-Doorbird
Good Morning.
How can I integrate my sonos devices to reproduce a Doorbird call in Comfortclick?

Token Name for shelly device
hi where can i the Token Name for shelly devices
im trying to read the temperature using a interger device as is showed in the mqtt video for BOS
but i do not know what is the token name to write.


Berker KNX BIQ switch and ''Thermostat'' Library example
Does anyone know if a change in setpoint performed with the physical switch affect the setpoint in bOS.
In other words, can you change setpoint with both? KNX physical switch and bOS? And it will sync. automatically?
Regards

Shelly & TCP listener
I have a little problem integrating Shelly through the tcp server
Shelly integration is in your libraries https://www.comfortclick.com/BOS/Library/Devices/115
Everything works fine except the listener.
The listener is configured as a tcp server, accepts connections but does not respond and does not close the session which causes Shelly to hang.
Shelly expects any response from the host or session closure.
I did the tests using https://docs.microsoft.com/pl-pl/dotnet/api/system.net.sockets.tcplistener?view=net-6.0
If the listener answers the call from Shelly or closes the session, everything works fine.
Conversely, when the host accepts the call and nothing returns or closes the session, Shelly stops sending calls to the host and suspends Shelly until a reset. Shelly appears to be waiting for any information from the host, without it being able to complete the routine.
In the code from the MS website from lines 45 to 63 there is a procedure that sends back to the client what the client sent, while on line 64 the connection is closed.
Removing these lines causes the problem and probably simulates comfortclicka operation.
Is there any call that will get a reply from comfortclick's website eg http://192.168.1.10/comfortclickreply?par=1?
Alternatively, you could add a checkbox as an option - "Send this message as confirmation:", "message" ?
checked on bOS v4.9.8 and Shelly 1 with fw 20220209-092750 / v1.11.8-g8c7bb8d

Bad communication between Jigsaw and MIM-B19N (MODBUS SAMSUNG)
Hi everyone,
i have a jigsaw connected to a Modbus interface module MIM-B19N Samsung. I have the next parameters:
I attach the datasheet of this module to compare if you need: Manual Interface MODBUS Maquinas clima Samsung.pdf
The question is that some times, randomly, the communication breaks down and we can control any of indoor units we have. In addition, i attach a screenshot of Jigsaw's logs:
I don't know if the problem is because of driver's parameters or firmware error. I will appreciate any help .
Thanks