Enter forum description here ...
0

Can we ask is device is OK or online?

Oti Dénia 3 years ago in bOS Configurator updated 3 years ago 5

Hello everyone

Is there any possibility to make the Comfort Click check the online status of the elements of the KNX bus?

heartbeat?

0
Under review

Colibri showing error to connect server

Bala Murugan 3 years ago in bOS Configurator / Devices updated by ComfortClick Support 3 years ago 1

Newly installed bOS configurator and connected to Colibri. When i enter the access ID and kept username & password default, but its showing error to connect server.

0
Under review

Connecting to KNX

Nathan Meinck 3 years ago in Devices / KNX updated by ComfortClick Support 3 years ago 1

Hi I'm having trouble connecting to KNX devises. I'm using Jigsaw, created a KNX devise and set  Connection Type 'Jigsaw', enabled the devise and it says connected.

Successfully imported the ETS file, the devise 'Hall Light' says not connected.

Any guidance / pointers would be much appreciated?

0

Doorbird

Eloy Larrañaga 3 years ago in Devices / Sonos updated 3 years ago 2

I need to be able to receive the video door entry call in comfortclick.

How can I send such a call to a sonos? 

I'm using comfortclick library file for this case. I supose the way is here but I'm unable to configurate it.

Image 3932

0

how to connect modbus analyzer 4 wire to a comfort click modbus dongle 2 wire?

Oti Dénia 3 years ago in Devices / Modbus updated by Fredrik Johansson 3 years ago 1

I need to integrate the measures of a Carlo Gavazzi WM12, but this has 4 wire connection.
Can you help me?
Thanks in advance.

WM12 CP v1r1 ENG 0903.pdf

WM12-DIN-96 IM ENG 0902.pdf
0

Integration Comfortclick-Sonos-Doorbird

Eloy Larrañaga 3 years ago in Devices / Sonos updated 2 years ago 1

Good Morning.

How can I integrate my sonos devices to reproduce a Doorbird call in Comfortclick?

0
Under review

Token Name for shelly device

Miguel Paredes 3 years ago in bOS Configurator / Devices updated by Ricardo Pinto | visiontech pt 3 years ago 4

hi where can i the Token  Name for shelly devices

im trying to read the temperature using a interger device as is showed in the mqtt video for BOS

but i do not know what is the token name to write.

Image 3920

Image 3921

0
Under review

Berker KNX BIQ switch and ''Thermostat'' Library example

Simen Hagen 3 years ago in bOS Configurator / Tasks updated 3 years ago 10

Does anyone know if a change in setpoint performed with the physical switch affect the setpoint in bOS.

In other words, can you change setpoint with both? KNX physical switch and bOS? And it will sync. automatically? 

Image 3904

Regards

0

Shelly & TCP listener

Krzysztof Szczepański 3 years ago in Devices / Basic updated 2 years ago 1

I have a little problem integrating Shelly through the tcp server

Shelly integration is in your libraries https://www.comfortclick.com/BOS/Library/Devices/115

Everything works fine except the listener.

The listener is configured as a tcp server, accepts connections but does not respond and does not close the session which causes Shelly to hang.

Shelly expects any response from the host or session closure.

I did the tests using https://docs.microsoft.com/pl-pl/dotnet/api/system.net.sockets.tcplistener?view=net-6.0

If the listener answers the call from Shelly or closes the session, everything works fine.

Conversely, when the host accepts the call and nothing returns or closes the session, Shelly stops sending calls to the host and suspends Shelly until a reset. Shelly appears to be waiting for any information from the host, without it being able to complete the routine.

In the code from the MS website from lines 45 to 63 there is a procedure that sends back to the client what the client sent, while on line 64 the connection is closed.

Removing these lines causes the problem and probably simulates comfortclicka operation.

Is there any call that will get a reply from comfortclick's website eg http://192.168.1.10/comfortclickreply?par=1?

Alternatively, you could add a checkbox as an option - "Send this message as confirmation:", "message" ?

checked on bOS v4.9.8 and Shelly 1 with fw 20220209-092750 / v1.11.8-g8c7bb8d

0

Bad communication between Jigsaw and MIM-B19N (MODBUS SAMSUNG)

Jose Jiménez 3 years ago in Devices / Modbus updated by Costel Miron 3 years ago 4

Hi everyone,

i have a jigsaw connected to a Modbus interface module MIM-B19N Samsung. I have the next parameters:

Image 3875

I attach the datasheet of this module to compare if you need:  Manual Interface MODBUS Maquinas clima Samsung.pdf


The question is that some times, randomly, the communication breaks down and we can control any of indoor units we have. In addition, i attach a screenshot of Jigsaw's logs:


Image 3877

I don't know if the problem is because of driver's parameters or firmware error. I will appreciate any help .

Thanks