Enter forum description here ...
0
Under review

Double digit month

Fredrik Johansson 2 weeks ago in bOS Configurator / Devices updated by ComfortClick Support 2 weeks ago 3

Hi,

is it possible to always have the month as double digit?

I have an API where I read the current year/month/day and insert in the request, and it is always expecting the month to be double digit as YYYY/MM-DD.

Between October-December there is no problem but between January-September I need to insert an extra "0" in the request.

Image 5316

0

No server access after upgrade

Mateus Laino 1 month ago in bOS Configurator updated 1 month ago 2

Hello, I inherited a project from another installer and there was already a server in the installation, I tried to access it and soon after a saver appeared informing that the version of the configurator (4.11.8) was very advanced and I needed to install a previous version of the configurator. I did it on the website and installed version 4.4.4.; I was finally able to access the server that asked for an update to continue and saved a backup to my desktop. After that I was never able to access the server through bos or via Web Browser. Another point is also that I tried to do the factory reset and I do

n't know if it's doing it because the lights are still intact (usually when you reset any equipment it restarts or something) but it seems that the server doesn't accept the factory reset. I need a solution for this because my client is in shock. Another point is that I can scan my network and the equipment app

ears with CC-JIGSAW with an ip assigned and the MAC address as well. But I can't access it.

Image 5300

Image 5301


Image 5299

0

Temperature not correctly imported

Francois Lesueur 2 months ago in Devices / Z-Wave updated by Jürgen Jürgenson 1 month ago 4

Hello, 

I have several Fibaro "eyes" : occupancy detectors that also provide temperatures. 

Sometimes, some of them return a silly temperature number like 155° for some time, can be several hours. 

Then, all of a sudden, they come back to a "normal" temperature like 20°C. 

That's a big problem as I'm using them to control heating.

Any ideas why this is doing this ? 

Thanks, 

François 

0

KNX writte

Constantin Larco 2 months ago in Devices / KNX updated by Ricardo Pinto | visiontech pt 1 month ago 7

Vent commands.pdf

Dear all.
Im facing a problem regarding the Fan configuratios and command as per attached PDF file.
Can you please help me ?

On the bOS log:

Users : 14/04/2025 17:44:01 : User : SetValue : Object: Devices\KNX\Ground floor\ISE + FA + H2O\AEF-1-GF RUN, Name: Value, Value: False

But the on the KNX is not present 

Thanks

Please see the pdf attached

0

Principle of integration at ComfortClick between KNX and Matter

Yaroslav Krashanytsia 2 months ago in Devices / Other 0

Hello. Tell me, how should the integration of matter look like? For example, I take three SONOFF Zigbee Thermostatic Radiator Valve TRVZB and pair them with Sonoff ZBBRIDGE-U, which supports Matter. Sonoff ZBBRIDGE-U is connected via the network with Comfortclick. Then I create Matter as a device at BoS Configurator and add these three thermostats directly to it as devices with the variables I need. I link the variables from Matter to the KNX group addresses and then I can control the temperature setpoint as KNX devices on the visualization. Did I understand the operating principle of this bundle correctly?

0

Bos Configurator Character Display Problem

ignazio cannizzaro 2 months ago in bOS Configurator updated by Jürgen Jürgenson 2 months ago 3

Hi after the last update the characters are displayed as in the screenshot.

Problema present on every pc

Solutions on how to solve?

thanks

Image 5274

0

Connecting remotely from another country

Osama Al-Areky 3 months ago in bOS Configurator updated by Jürgen Jürgenson 3 months ago 4

Hello, 

I am trying to connect remotely to my server to Bos configurator from far location, another country, is it a possible thing? I thought I would be able to do that with the public IP address but this doesn't work and it shows me the error message on the photo below. Is there something missing or should I do something else to connect or it is maybe impossible to conenct remotely from another country?  

Image 5267

0

modbus Unsigned 8 bit

Steven 3 months ago in Devices / Modbus updated by Jürgen Jürgenson 3 months ago 3

Image 5264

How to read 8-bit Modbus registers? When I try to read a value with a 16-bit unsigned register, I get the error message: Package error 43031: ILLEGAL DATA ADDRESS - Starting address invalid or starting address + quantity invalid

0

Modbus settings

constantin larco 3 months ago in Devices / Modbus updated by Jürgen Jürgenson 3 months ago 1

Dear all

I have to monitorize a generator using the modbus connection.

I manage to conect the software to the generator, the adress is 2, as you can see from the file shared.

But the readings from the software are not corect, if i use the ModScan32 the readings are corect, please note that i use the same 485/USB in both cases.

Can you please give me some hints with the settings ?

Thanks

Confort Click Boss MODBUS.pdf

0

More symbols

Dan Sharpe 4 months ago in bOS Configurator / Devices updated by Jürgen Jürgenson 3 months ago 4

Hello

Is there anyone that have some more symbols, especially different kinds of light symbols, like ceiling spot lights?