+1
Under review

Denon HEOS

Yannick Bruynseels 6 years ago in bOS Configurator updated by Joost vB 1 year ago 14

Hello,


will there be a plugin for the Denon Heos system? This is similar to Sonos but better quality and better for integrators.


Thanks,

Yannick

+1
Under review

Error message appearing when viewing IP Camera sources in ffmpeg component.

Pascal Platteel 6 years ago in Devices / Cameras updated by ComfortClick Support 6 years ago 1

When viewing at camera streams configured throug OnVif, I get the following error's a lot:


Devices : 08/08/2018 11:42:00 : Error : Devices\IP Camera Garage : Error running ffmpeg. Destination array was not long enough. Check destIndex and length, and the arrays lower bounds.    at System.Array.Copy(Array sourceArray, Int32 sourceIndex, Array destinationArray, Int32 destinationIndex, Int32 length, Boolean reliable)
   at ComfortClick.IPCamera.Helpers.MpegDecoder.Streamer()

How can this be fixed?

+1

UPS and UPS generic and Jigsaw

Francois Lesueur 6 years ago in Devices / Other updated by Paul G 3 years ago 1

Hello,


What is the difference between ""UPS and "UPS generics" devices ? 


The help says that the UPS device is using the Windows drivers, and then can work only on bOS windows based systems. Are there / will there be any support for Jigsaw models ? Maybe with the UPS generic device ?

+1

logic "ID" 2BF

I need to be able to perform an "ID" with a 20ºC value of 2BF. How can I do it
+1

DMX integration

Hi, 

Because now dimmable LEDS are the way to go for home lightning, DMX protocol seems very interesting because it is cheap. There is no status update, but this isn't important for home lightning. Do you have any plans to implement integration with some DMX usb controllers? 

I am going to test DMX sending http requests from CC to a nodejs server on raspbarry pi which will be connected to a cheap usb dmx convertor with FTDI chip (FT232RL).

+1

test

Tilen Suhadolnik 6 years ago in Devices / Modbus updated 6 years ago 0

test

+1
Under review

Status value collection

Guillem Morey 6 years ago in bOS Configurator / Themes updated 6 years ago 8

I have an issue with this property, if I use integer value it works correctelly, but if I use a double float just works "EqualorGreater" and "EqualorLess" but not "equal".

Any idea?

Thanks

+1
Under review

Scene name

Kristián Vojčík 7 years ago in bOS Configurator updated by ComfortClick Support 7 years ago 1

Hello. I want to ask if it is possible to change name in scene object, like change name of light or blind by user or without renaming it in ETS directory, similiar to adding light to room you can rename it however you want. Thanks

+1
Under review

Variable HTTP Header in PUT Command

Lee Douglas 7 years ago in Devices / Http updated by ComfortClick Support 6 years ago 4

Working on integration with the HIVE system from British Gas.

I need to send a "login" command through the API to receive a SessionID.

Which I can do easily in bOS.

I then need to pass this SessionID into each later command as a header for authorisation. As the SessionID varies every 30 minutes or so, I need to have the "SessionID" as a variable Header in later commands.

Are you able to amend Config to allow for variables in POST command headers?

(I note we can already use variables in several other places of the command, just not the header which I need).


Specifics:


URL is: https://api-prod.bgchprod.info:443/omnia/nodes

Command is GET.


The header I need to use is:

Content-Type: application/vnd.alertme.zoo-6.0+json
Accept: application/vnd.alertme.zoo-6.0+json
X-Omnia-Client: Hive Web Dashboard
X-Omnia-Access-Token: Irg6fxvdBrhE0xewMiGJxo4


Where the final highlighted section varies every 30 minutes.

0

The sensibo integration is not allways working

Joaquim Matos 3 weeks ago in Devices / Http updated 3 weeks ago 2

The integration using the available HTTP example no longer works properly and the following happens:

- every two minutes the connection is established

- Lasts about 30s and turns off again

- I can't find any parameter with these values in the configuration

- during the 30s I can give commands, for example on/off, but after that it's not possible, although sometimes I can (it's random).

- The response message is "ok" when the connection is achieved and "TooManyRequests" when there is no connection.

Can you help please