bOS 4.9+ update
Hello,
I see that I need to update my software but I am afraid of the warning message as I haven't done this before and I feat it could cause any hardware issue or in the server or the configuration?
Thank you.

bOS Config v 4.11.2 windows 7
Hello,
After updating bOS Configurator to v 4.11.2 I am receiving an error:
How can i fix this error?
Thanks.

How to configure and use plugin Telegram
Hi,
First of all, I wish you Happy New Year !!!
I would like to send Notification with plugin Telegram. I have created a user and a bot from Telegram. All is right.
So, in bOS I don t know where to fill in User, password for Telecam and so on ... Some one can explain to me how to fill in and use plugin Telegram in bOS please ?
Regards,
Michael

BACnet Priorities, Integration of 3rd party devices
Hello everyone,
I am currently using Jigsaw Pro for home automation and have integrated a Siemens PXC4 controller along with an RDG260KN/BK thermostat via BACnet/IP. While the integration works well overall, I’ve encountered a couple of challenges related to BACnet write priorities and multistate commands.
Challenge 1: BACnet Write Priority
When writing values, such as temperature setpoints or operation modes, to the Siemens controller through Jigsaw Pro, the values seem to be written at BACnet priority 8. This priority level acts as a manual override in the Siemens PXC4 controller. However, for my application, I need these values to be written at BACnet priority 13, which corresponds to normal operation without overriding.
I’ve tested the PXC4 using BACnet browsers like Yabe and Siemens BACnet Browser, and I can successfully write values at priority 13 from those tools. I’m wondering if Jigsaw Pro supports specifying the write priority for BACnet points and, if so, how this can be configured within the system.
Challenge 2: Multistate BACnet Commands
In addition, I need to configure a multistate BACnet point for the thermostat's operation mode. Specifically, I want to send:
- Value 2 for Off
- Value 5 for Cooling
Could someone guide me on how to configure these specific multistate commands in Jigsaw Pro? I also need to ensure that these commands are written at BACnet priority 13.
I would appreciate any guidance or suggestions from the community or the ComfortClick support team to help resolve these issues.
Thank you in advance for your assistance!

Switch on a scene using movement detector task
Hi, I tried to use the movement detector task to trigger a scene. The status of the scene updates to ON when the movement detector value is true, but not the actual brightness values of the lights implemented in the scene. Is there a feedback that needs to programmed?
Also I use a KNX switch to actuate the same scene, KNX switch sends a 1byte telegram to trigger the scene, the scene contains both 1byte ''brightness values'' and 1bit ''switching'' group adresses for lights. This works fine.
What is the best way to integrate a movement detector? I want the scene to work both from the KNX switch and the KNX movement detector.
Regards
Simen

HikVision alrm with SIA-DCS protocol
Hikvision Alarm Panel protocols.jpg
Hello everyone,
I have an HikVision alarm system wich are using SIA-DCS protocol, how can I integrate on JigSaw & bOS Config?
Thank you
Nelu

webhooks
does anybody have any experience using webhooks on the jigsaw pro?
I want to integrate my unify G4 doorbell's fingerprintscanner, to open my door, and i have a jigsaw running my KNX.
If i can get the G4 to communicate with my KNX, i could make it happen

Fibaro Radiator Thermostat
Fibaro radiator thermostat error message Devices : No response to Battery.
Every hour for each valve.
It is set to: Enable polling
It transmits the battery charge value at the set interval with polling.
But why does it put a No response to Battery error in the LOG?

Jigsaw CC J-2 not discoverable
Hi,
Already installed Jigsaw CC-JS-2 bought in 2022.
We already install Configurator, but after change passw the device is not discoverable on WiFi.
We are trying to Restore Factory Settings took 30s push the reset button, nothing happened.
On IPScanner not appear anymore
Please let me know what we can do? Can you connect on remote to fix the issue?

Error connecting to device. Write: Unable to cast object of type System.Int32 to type System.Double.
KNX disconnect two times a minute. Any ideas what could be wrong ? 5 years was no problem, with last update 4.11.8 problem started.