how to create a while loop

Gruyère Energie SA 5 years ago in bOS Configurator updated by Kristián Vojčík 5 years ago 6

I would like increment value until the knx switch are pressed. 

I think use the program fonction but I dont' know how to create a quick while loop ?

0
Under review

How to use Scenes with the new HUE Parameter set?

Geir Hardt 6 years ago in bOS Configurator / Devices updated by Ricardo Pinto | visiontech pt 5 years ago 12

Hi
After ugrading to the new version of bOS, my scenes containing HUEs are not getting recogniczed any more.
What do I need to configure in a sceene to make the sceene recognize that the room setting are according to the sceene?
In the previous version, The color values of the light was enough for a scene to be recongnized.
I have tried with most combinations 
of  HUE.Power with HUE.Brightness, HUE. Color Temperature and HUE.Color with little success. The scene's State does not seem to be set consistently. 
Is there an explanation of how to use Scenes with HUEs after version 4.4.4?



0
Under review

Serial Port - No Ack Error

Nuno Filipe 6 years ago in bOS Configurator / Devices updated by Nuno Filipe 4 years ago 12

I'm trying to connect a Paradox security system to a CC Grinder, through a Paradox PRT3 module USB (COM3), and I'm getting a "Error connecting to device - No Ack" message" 10 seconds after connection, keeps trying to connect.

Can't figure if its a Windows problem (tried several configurations for flow control on port settings), Paradox configuration (Serial Port ON, Automation ON, ASCII Protocol, 9600br) or CC.

Any ideas?

0
Under review

Aeotec Trisensor not visible in bOS Configurator

Alberto 6 years ago in Devices / Z-Wave updated by ComfortClick Support 6 years ago 1

Dear all,

I'm trying to add Aeotec Trisensor to my Z Wave network but the device is not visible in bOS Configurator.

The sensor is paired with my Aeotec Stick Gen 5 but un-visible in the Comfortclick.

Any idea on how to fix it?

0

Curtain or Music play after bOS Launched

BRIAN BUI 6 years ago in bOS Configurator updated by Fabien Fuster 6 years ago 1

Hello,

I am having an issue when bOS Launch. 


It always automatically open/close my curtain, as well as play my music right after bOS Running. This is annoying.

Do you know how to disable this function.

Thank for your help

0

Calculation in the last second of each month

SYSGLOB LDA 6 years ago in bOS Configurator / Tasks updated 6 years ago 2

Hi everyone.

I need help from you guys. 

As anyone had the need to do a math calculation in the last second of each month? 

My idea is to present the client with the difference between this month energy consumption comparing to the last month. 

The math is easy, my problem is with the trigger, because we have months with 29 or 30 or 31 days.
So I need to do the calculation ( Double = Thismonthcount - Previousmonthcount ) in the last second of each month. 

Thanks for the help.

0
Under review

Graph problem

Noel Fuentes 6 years ago in bOS Configurator / Tasks updated 6 years ago 7

Hi,

Something weird is happening with the graphs.

I have 8 HVAC zones with an analog log for set temperatura and another one for room temperature each. Well, I've added to the visualization a data logger (opengraph button) for every zone and added to it the 2 analog logs.

Everything was fine with the first 6 zones. 7th and 8th zones only work fine if I add to the graph only one log. If i add a second log to it, a error shows when I try to open the graph in the visualization. Then I open the graph in the config and one of the two logs is missing, showing the first one and another one with the "Building" node (see image attached).

Image 2324

Is this only happening to me?

Thanks in advance.


Best regards,

0

Percent Setter object - missing parameter

Grzegorz Kulinski 6 years ago in bOS Configurator / Themes updated 6 years ago 0

Hi,

After upgrading to version 4.6.24, one customer noticed a change in the control of dimmable lights. In earlier versions of bOS Configurator it was possible to set the precision separately for the slider on the button ("bar steps" parameter) and the one that appears after pressing the button ("setter steps" parameter). In the latest version only the first of these parameters is available. Is it intended action or a bug?
I don't know how many versions back this function has disappeared because I updated the system from version 4.6.1.

Image 2318

Image 2319

Regards,
Grzegorz

0

Relay board C0135 Integration with Comfortclick

Alexander Paredes 6 years ago in Devices / Modbus updated 5 years ago 8

Hi. i would like to know how this Relay board can work with comfortclick

it use MODBUS RTU and can be controlled Using the software in this Site,

also there is a guide on the website, http://www.bizkit.ru/en/2018/12/13/7222/

Image 2290

0
Under review

Help on getting data from http response

Dave De Busschere 6 years ago in Devices / Http updated by Ricardo Pinto | visiontech pt 5 years ago 57

I'm  trying to get data from the respnonse "actualvolume" 

I've been exploring the forum here but i can't figure out what i'm doing wrong.


Parse type: Jhson

I get this response:

{"?xml":{"@version":"1.0","@encoding":"UTF-8"},"volume":{"@deviceID":"C4F312D5994F","targetvolume":"16","actualvolume":"16","muteenabled":"false"}}

Image 2282

Image 2283

Image 2284


Image 2288